 SILICON RECTIFIER
VOLAGE RANGE 50 to 600 Volts CURRENT 15 Ampere
FEATURES
SPA1501 THRU SPA1505
* Low cost * Low leakage * Low forward voltage drop * High current capability * High surge current capability * Ideal for solar panel PV application such as By-Pass diode
R-7
MECHANICAL DATA
* * * * *
Case: Molded plastic Epoxy: Device has UL flammability classification 94V-O Lead: MIL-STD-202E method 208C guaranteed Mounting position: Any Weight: 2.08 grams
.96 (24.5) MIN.
.064 (1.6) MAX
.360 (9.1) .340 (8.6)
.360 (9.1) DIA. .340 (8.6)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load.
.96 (24.5) MIN.
Dimensions in inches and (millimeters) MA X IMUM R AT ING S (At TA = 25 C unless otherwise noted) RATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum DC Forward Current @TL=125 oC(Note 2) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time Typical Junction Capacitance (Note) Typical Thermal Resistance Operating Temperature Range Storage Temperature Range ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 15A DC @TA = 25 o C Maximum DC Reverse Current at Rated DC Blocking Voltage @TA = 100 o C Maximum Full Load Reverse Current Average Full Cycle .375" (9.5mm) lead length at TL = 75 oC NOTES : 1. Measured at 1 MH Z and applied reverse voltage of 4.0 volts 2. Heat-sink mounted 10mm max from body SYMBOL VF IR SPA1501 SPA1502 SPA1503 1.0 10 100 50 SPA1504 SPA1505 UNITS Volts uAmps uAmps 2009-10 REV:O SYMBOL VRRM VRMS VDC IO IFSM IT CJ R JA TJ TSTG
2
o
SPA1501 50 35 50
SPA1502 100 70 100
SPA1503 200 140 200 15 400 663.7 125 7
SPA1504 400 280 400
SPA1505 600 480 600
UNITS Volts Volts Volts Amps Amps A 2S pF
0
C/ W
0
175(Tj<200oC in Bypass Mode) -55 to +175
C C
0
RATING AND CHARACTERISTIC CURVES ( SPA1501 THRU SPA1505 )
AVERAGE FORWARD CURRENT, (A)
FIG. 1 - TYPICAL FORWARD CURRENT DERATING CURVE
26 20 14 10 6 2 0
Single Phase Half Wave 60Hz Resistive or Inductive Load
D.C with heat sink
0
20 40 60 80 100 120 140 160 180 200 AMBIENT TEMPERATURE, ( )
FIG. 3 - TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT, (uA)
1000
INSTANTANEOUS FORWARD CURRENT, (A)
FIG. 2 - TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
100
100
10
TJ = 100
10
TJ = 25 Pulse Width=300uS 1% Duty Cycle
1.0
1.0
.1
TJ = 25
.1 .6
.8 1.0 1.2 1.4 1.6 1.8 2.0 INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG. 3 - MAXIMUM NON-REPETITIVE FORWARD
.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
PEAK FORWARD SURGE CURRENT, (A)
600 500 400 300 200 100 0 1 2
THERMAL RESISTANCE (J /W)
SURGE CURRENT
FIG. 5 - TYPICAL THERMAL RESISTANCE VS LEAD LENGTH 25 20 15 10 5 0 0 .1 .2 .3 .4 .5 .6 .7 .8 .9 1.0 EQUAL LEAD LENGTH TO HEAT SINK, (IN.)
TJ = 25
5 10 20 50 NUMBER OF CYCLES AT 60Hz
100
Marking Description
Rectron Logo Part No.
VYM
1 5 AX
Cathode Band Year - code: (Y:Last digit of year) Month - code: (M:0~9,O,N,D) Voltage-code
01-------50V 02-------100V 03--------200V 04------400V 05------600V
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.